DOUT21.STATEU to DOUT32.STATEU
Description
DOUTx.STATEU sets the state of the digital output node as follows:
0 = deactivated
1 = activated
DOUTx.STATEU is used when DOUTx.MODE = 0 (user mode).
General Information
Type |
R/W Parameter |
Units |
N/A |
Range |
0 to 1 |
Default Value |
0 |
Data Type |
Integer |
Start Version |
M_01-01-01-000 |
Variants Supported
Supported by any AKD with extended IO.
Fieldbus Information
If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type.
Parameter | Fieldbus | Address | Attributes | Signed? |
---|---|---|---|---|
DOUT21.STATEU |
PROFINET |
2736 | Byte | No |
Sercos® III | 2 Octets | |||
DOUT22.STATEU |
PROFINET |
2741 | Byte | |
Sercos® III | 2 Octets | |||
DOUT23.STATEU |
PROFINET |
2746 | Byte | |
Sercos® III | 2 Octets | |||
DOUT24.STATEU |
PROFINET |
2751 | Byte | |
Sercos® III | 2 Octets | |||
DOUT25.STATEU |
PROFINET |
2756 | Byte | |
Sercos® III | 2 Octets | |||
DOUT26.STATEU |
PROFINET |
2761 | Byte | |
Sercos® III | 2 Octets | |||
DOUT27.STATEU |
PROFINET |
2766 | Byte | |
Sercos® III | 2 Octets | |||
DOUT28.STATEU |
PROFINET |
2771 | Byte | |
Sercos® III | 2 Octets | |||
DOUT29.STATEU |
PROFINET |
2776 | Byte | |
Sercos® III | 2 Octets | |||
DOUT30.STATEU |
PROFINET |
2781 | Byte | |
Sercos® III | 2 Octets |
Parameter | Register Address | Is 64 bit? | Attributes | Signed? |
---|---|---|---|---|
DOUT21.STATEU | 1472 | No | 8 bit | No |
DOUT22.STATEU | 1482 | |||
DOUT23.STATEU | 1492 | |||
DOUT24.STATEU | 1502 | |||
DOUT25.STATEU | 1512 | |||
DOUT26.STATEU | 1522 | |||
DOUT27.STATEU | 1532 | |||
DOUT28.STATEU | 1542 | |||
DOUT29.STATEU | 1552 | |||
DOUT30.STATEU | 1562 |